Copyright Digital Equipment Corp. All rights reserved.

FLOCONFAI

 NUMBER:  95

 ERROR CODE:  E

 MESSAGE TEXT:  floating point conversion failed

 EXPLANATION:  The attempted unformatted read or write of non-native
 floating-point data failed.  One of the following conditions
 occurred for a non-native floating-point value:

  o  When using VAX data types in memory (/FLOAT=G_FLOAT or
     /FLOAT=D_FLOAT), the value exceeded the allowable maximum value
     for the equivalent native format and was set equal to invalid.

  o  When using VAX data types in memory (/FLOAT=G_FLOAT or
     /FLOAT=D_FLOAT), the value was infinity (plus or minus),
     Not-a-Number (NaN), or otherwise invalid and was set to
     invalid.

  o  When using IEEE data types in memory (/FLOAT=IEEE_FLOAT), the
     value exceeded the allowable maximum value for the equivalent
     native format and was set equal to infinity (plus or minus).

  o  When using IEEE data types in memory (/FLOAT=IEEE_FLOAT), the
     value was infinity (plus or minus) and was set to infinity
     (plus or minus).

  o  When using IEEE data types in memory (/FLOAT=IEEE_FLOAT), the
     value was invalid and was set to Not-a-Number (NaN).


 Make sure the correct file was specified.  Make sure the record
 layout matches the format VSI Fortran is expecting.  Check that
 the correct non-native floating-point data format was specified, as
 described in the HP Fortran for OpenVMS User Manual.

 This error is not returned by IOSTAT.