Copyright Digital Equipment Corp. All rights reserved.

SETPARAMS

   The SETPARAMS phase uses as its input the SETPARAMS.DAT file
   created during the GENPARAMS phase. In this phase, AUTOGEN runs
   SYSMAN to update the system parameter values in the default
   parameter file.

   On VAX systems, the default parameter file is
   SYS$SYSTEM:VAXVMSSYS.PAR. AUTOGEN saves the current system
   parameters in the file SYS$SYSTEM:VAXVMSSYS.OLD before updating
   these parameters in SYS$SYSTEM:VAXVMSSYS.PAR. The new values are
   also saved in SYS$SYSTEM:AUTOGEN.PAR.

   On Alpha systems, SYS$SYSTEM:ALPHAVMSSYS.PAR is the default
   parameter file. AUTOGEN saves the current system parameters
   in the file SYS$SYSTEM:ALPHAVMSSYS.OLD before updating these
   parameters in SYS$SYSTEM:ALPHAVMSSYS.PAR. The new values are also
   saved in SYS$SYSTEM:AUTOGEN.PAR.

   On I64 systems, SYS$SYSTEM:IA64VMSSYS.PAR is the default 
   parameter file. AUTOGEN saves the current system parameters 
   in the file SYS$SYSTEM:IA64VMSSYS.OLD before updating these 
   parameters in SYS$SYSTEM:IA64VMSSYS.PAR. The new values are 
   also saved in SYS$SYSTEM:AUTOGEN.PAR.

   The SETPARAMS phase is valid as a start phase and an end phase.
   SETPARAMS requires the SYSPRV and OPER privileges.