VMS Help  —  ROBOT  INJECT
    The INJECT command moves a cartridge from a port to a slot.

    Format

    INJECT [PORT port_number] SLOT slot_number [ROBOT robot_name]

1  –  Parameters

    port_number - An integer value indicating the robot port.

    slot_number - An integer value indicating the robot slot.

    robot_name - The name for the media robot.

2  –  Example

    The following MRU example injects a cartridge from the inport
    of a TL820 Automated Tape Library to slot 19:

    $ ROBOT INJECT PORT 0 SLOT 19 ROBOT $1$DUA0