The Analyzer plots and displays the results of the vector
instructions data gathered in the Collector. You can use three
views to aid in the analysis of the scalar/vector processor
parallelism: Table, Histogram, and Annotated Source.
You can set the data kind to the any of the following, depending
on what was gathered by the collection run:
o Vector instructions counted
o Vector PC sampling
o Vector CPU sampling
The following additional domains are available with vector
instruction analysis:
o INSTRUCTIONS-Sets the domain to be the vector instruction
found at the sampled or counted PC.
o VLENGTH-Sets the domain to be the Vector Length Register (VLR)
values
o VMASK-Sets the domain to be the Vector Mask Register (VMR)
values
o VOPCODE-Sets the domain to be specific vector instructions
o VOPERATIONS-Sets the domain to be the number of operations per
Vector instruction
o VREGISTERS-Sets the domain to be the Vector Register usage
o VSTRIDE-Sets the domain to be the Vector Stride values