HELPLIB.HLB  —  PMDF  POPSTORE  SET

1  –  DOMAIN

    Select the user domain to manage.

    Syntax

      SET DOMAIN  domain-name

    Command Qualifiers             Defaults

    None

1.1  –  Parameters

 domain-name

    Name of the user domain to manage.

1.2  –  Description

    By default, the DEFAULT user domain is managed with this utility.
    To manage a different user domain, select that domain with the
    SET DOMAIN command.

    For example, to manage the EXAMPLE.COM domain, specify

    popstore> SET
    Using the "default" user domain
    ...
    popstore> SET DOMAIN EXAMPLE.COM
    popstore> SET
    Using the "example.com" user domain
    ...
    popstore>

2  –  STORAGE_UNITS

    Set the units used to measure byte-counted values.

    Syntax

      SET STORAGE_UNITS  type

    Command Qualifiers             Defaults

    None

2.1  –  Parameters

 type

    Type of units to use. Must be one of BYTES, KBYTES, MBYTES, or
    GBYTES.

2.2  –  Description

    By default, units of KBYTES (1024 bytes) are used when specifying
    values for byte-count valued fields such as message quotas.

    To select a unit of measure other than KBYTES, use the SET
    STORAGE_UNITS command. BYTES selects bytes, KBYTES selects
    1024 bytes, MBYTES selects 1024 KBYTES, and GBYTES selects 1024
    MBYTES.

    After issuing a SET STORAGE_UNITS command, all byte-count valued
    numbers input on the command line will be interpreted as being
    measured in the newly selected units. Note that displayed values
    are displayed in the units called for by the formatting template
    used to generate the display.

    For example, to use units of megabytes, specify

    popstore> SET STORAGE_UNITS MBYTES

3  –  TIME_UNITS

    Set the units used to measure time-valued fields.

    Syntax

      SET TIME_UNITS  type

    Command Qualifiers             Defaults

    None

3.1  –  Parameters

 type

    Type of units to use. Must be one of SECONDS, MINUTES, HOURS, or
    DAYS.

3.2  –  Description

    By default, time units of DAYS are used when specifying values
    for time-valued fields. Presently, the only time-valued field
    is the total connect time field which can be modified with the
    /TOTAL_CONNECT qualifier of the MODIFY command.

    To select a unit of measure other than DAYS, use the SET TIME_
    UNITS command. After issuing a SET TIME_UNITS command, all time-
    valued numbers input on the command line will be interpreted as
    being measured in the newly selected units. Note that displayed
    values are displayed in the units called for by the formatting
    template used to generate the display. For example, to use units
    of HOURS, specify

    popstore> SET TIME_UNITS HOURS
Close Help