/OPTION_FILE[=file-spec]
/NOOPTION_FILE (default)
CLBUILD can optionally produce a command option file that
contains correct table sizes to hold the command definitions
which were just compiled (plus a little room for growth). The
/OPTION_FILE qualifier causes this file to be read as input and
a new such option file created as output. If /OPTION_FILE is
specified with no value, then the file written will have the
same name as the input command definition file, but with the file
extension .COP; for instance, if the file PMDF_COM:PMDF.CLD was
the input parameter, then the default name for the output command
option file would be PMDF_COM:PMDF.COP. If the /NOOPTION_FILE
qualifier is specified (the default), then no option file will be
output.
Note that use of the /MAXIMUM qualifier causes CLBUILD to read
options from MAXIMUM_COMMAND.DAT in addition to any command
option file. This file specifies near maximum table sizes. Only
use this qualifier if the current table sizes are inadequate,
and only use it to create a new command option file. The /NOIMAGE
qualifier should always be specified when /MAXIMUM is specified
since a maximum-size image would be truly enormous and extremely
wasteful.