Use the SET MODULE X25-SERVER command to create or modify the
parameters of the X25 Call Handler in the volatile data base. Use
the DEFINE MODULE X25-SERVER command to create or modify the
parameters of the X25 Call Handler in the permanent data base.
The components contain records that identify a destination,
specify parameters for this destination, specify the maximum
number of circuits that each module (that is, all destinations
for a particular module) may have, and specify the state of the
module.
Specify the module parameters and the destinations using
separate SET or DEFINE MODULE X25-SERVER or X29-SERVER commands.
Format:
SET MODULE X25-SERVER ALL
X29-SERVER COUNTER TIMER seconds
MAXIMUM CIRCUITS count
STATE ON
OFF
SHUT
DESTINATION dest-name ACCOUNT account
KNOWN DESTINATIONS CALL MASK hex-value
CALL VALUE hex-value
CALLED ADDRESS dte-address
EXTENSION MASK hex-string
EXTENSION VALUE hex-string
GROUP group-name
INCOMING ADDRESS dte-address
NETWORK network-name
NODE node-id
OBJECT object-id
PASSWORD password
PRIORITY priority
RECEIVING DTE dte-address
REDIRECT REASON code
SENDING ADDRESS dte-address
SUBADDRESSES range
USER user-id
All underscores found in parameters must be replaced with spaces
when parameters are used in NCP commands.
1 – ALL
Copies the Call Handler parameters from the permanent data base into the volatile data base. (Used only for the SET MODULE X25-SERVER command or the SET MODULE X29-SERVER command.)
2 – KNOWN DESTINATIONS
Specifies all known destinations.
3 – COUNTER TIMER seconds
Sets a timer whose expiration causes a server module counter logging event. Specify a decimal integer in the range 1 to 65,535.
4 – MAXIMUM CIRCUITS count
Specifies the maximum number of circuits that the module (that is, all destinations) may have. By default, the maximum is 255.
5 – STATE
Specifies the operational state of the server module. This parameter
takes one of the following values:
ON The module is available for normal use.
OFF The module is not in use.
SHUT The module is to be closed down but only when all
present activity has ceased. (The SHUT value applies only
to the SET MODULE X25-SERVER or X29-SERVER command.)
For the X25 server module, the default state is ON. For
the X29 server module, the default state is OFF.
6 – CALLED ADDRESS dte-address
For redirected calls, this parameter identifies the DTE that was originally called. The parameter value is used to select a destination for a redirected call. By default, no called DTE is used.
7 – DESTINATION dest-name
Identifies a destination or specifies all known destinations. Dest-name is an id string. Associate parameters with the destination or destinations, as follows:
8 – ACCOUNT account
Identifies the user account for use by incoming calls to the destination. Specify a string of from 1 to 39 characters. By default, no account is used.
9 – CALL
9.1 – MASK hex-value
Specifies the mask applied to the incoming call data before it is tested. Hex-value is a string of 2 to 32 hexadecimal digits. By default, no mask is used.
9.2 – VALUE hex-value
Specifies the string used to test the incoming call data. Hex-value is a string of 2 to 32 hexadecimal digits. By default, no value is used.
10 – EXTENSION
10.1 – MASK hex-string
Provides a mask for the called address extension facility. Using logical AND, the mask is merged with the called address extension in the incoming call and the result is compared with the extension value. By default no extension mask is used.
10.2 – VALUE hex-string
Provides a value for the called address extension facility. This value is compared with the address extension in the incoming call (after merging as described in EXTENSION MASK). By default no extension value is used.
11 – GROUP group-name
Identifies a closed user group (CUG) or bilateral closed user group (BCUG). The group-name is an id string. By default, no group name is used.
12 – INCOMING ADDRESS dte-address
Identifies the address of the DTE receiving the call (as specified in the call packet).
13 – NETWORK net-name
Specifies the network for which calls are accepted. By default, no network name is used.
14 – NODE node-id
Identifies the host node which is to be the destination of the incoming X25 call.
15 – OBJECT object-id
Identifies the object that is activated when an incoming call arrives. The object-id is an id string. If the object name looks like a number, enclose the string in quotes. This parameter is mandatory when you specify a destination for the first time.
16 – PASSWORD password
Specifies the password for use by incoming calls to the destination. Specify a string of from 1 to 39 characters. The default is that no password is used.
17 – PRIORITY priority
Specifies the priority of the destination record and is used to select one of a set of destinations for which the incoming call may be valid. Specify a value in the range 0 to 255, where 255 is the highest priority. By default, priority takes a value of 0.
18 – RECEIVING DTE
Identifies the local DTE. IT is used to select a destination for calls received on the local DTE. By default, no receiving DTE is used.
19 – REDIRECT REASON code
Identifies a reason for redirecting an incoming call. The reason code
can take one of the following values:
BUSY The original DTE was busy and could no accept any
more calls.
OUT OF ORDER The original DTE was out of order.
SYSTEMATIC All calls to the original DTE are automatically
rerouted.
The reason code is used to select a destination for a redirected
call. By default, no reason is used.
20 – SENDING ADDRESS dte-address
Identifies the address of the remote DTE that originated the call. By default, no sending DTE is used.
21 – SUBADDRESSES range
Specifies the range of local DTE subaddresses that identify the destination for the incoming call. Range consists of one or two subaddresses. Subaddress is a decimal integer in the range 0 to 9999. Separate two subaddresses with a single hyphen to indicate a range. The second subaddress must be greater than the first. By default, no subaddress range is used.
22 – USER user-id
Specifies the user identification for use by incoming calls to the destination. Specify a string of from 1 to 16 characters. The default is that no user identification is used.