SHWCLHELP.HLB  —  ADD
  Modifies the current display by including the specified field or
  class in the display.  The ADD command can also be used to include
  the following in the display: circuits that are in a particular state,
  connections that are in a particular state or of a particular name, or
  systems of a particular node name, system ID, or hardware type.

  Format:  ADD class[,...] [/qualifier...] [field[,...]] [/qualifier...]

  Examples: ADD CIRCUITS,CONNECTIONS,LOC_CONID,REM_CONID
            ADD CIRCUITS/TYPE=ALL, CONNECTIONS/TYPE=NOOPEN

1  –  Qualifiers

  Qualifiers apply only to class names.

  The /ALL qualifier can be used to add all the fields in a particular
  class to the display.  Additional qualifiers apply only to the SYSTEMS,
  CIRCUITS and CONNECTIONS classes.

  For additional information, see help on ADD examples and ADD class.

2  –  Field

  Specifies the field or fields to be added to the current display.

  Format:  ADD field[,...]

  NOTE: For a complete list of field names, type HELP FIELDS from the
        command prompt. If the list of fields scrolls off your terminal,
        enter SET SCREEN=132 or refer to the OpenVMS System Management
        Utilities Reference Manual. For a list of field names in a
        particular class, type HELP CLASSES class-name from the command prompt.

3  –  Class

  Specifies the class or classes to be added to the current display.

  Format:  ADD class[,...] [/qualifier,...]

  NOTE:  For a description of each class and the field names
         within each class, type HELP CLASSES from the command prompt.

3.1  –  CLUSTER

  Adds the Cluster class to the display.

3.1.1  –  Qualifiers

3.1.1.1    /ALL

  Adds all the fields in the Cluster class to the display.

  Format:  ADD CLUSTER/ALL

3.2  –  SYSTEMS

  Adds the Systems class to the display.  Optionally, specific
  systems can be added to the display.  The systems to be added
  can be specified by type, system ID number, or node name.
  By default all systems are displayed.

  Format:  ADD SYSTEMS [/qualifier,...]

3.2.1  –  Qualifiers

3.2.1.1    /ALL

  Adds all the fields in the Systems class to the display.

  Format:  ADD SYSTEMS/ALL

3.2.1.2    /ID

  Specifies the system ID number of the system to be added to the
  display.  The system is assumed to be removed from the display
  via the REMOVE SYSTEMS/ID or /NODE commands.  To specify a
  hexadecimal value as the ID number, precede the value with %X.
  Optionally, ALL can be specified to restore all SYSTEMS that were
  previously removed via the REMOVE SYSTEMS/ID or /NODE commands.

  Format:  ADD SYSTEMS/ID=(system-ID[,...])
           ADD SYSTEMS/ID=ALL

  If only one system ID is specified, the parenthesis can be omitted.

  Examples:  ADD SYSTEMS/ID=101
             ADD SYSTEMS/ID=(206,%XF2A)

3.2.1.3    /NODE

  Specifies the node name of the system(s) to be added to the display.
  The system is assumed to be removed from the display via the REMOVE
  SYSTEMS/ID or /NODE commands. Optionally, ALL can be specified to
  restore all SYSTEMS that were previously removed via the REMOVE
  SYSTEMS/ID or /NODE commands.

  Format:  ADD SYSTEMS/NODE=(node-name[,...])
           ADD SYSTEMS/NODE=("node-name"[,...])
           ADD SYSTEMS/NODE=ALL

  If only one node name is specified, the parenthesis can be omitted.
  Quotation marks are optional except when specifying a system
  with a node name of "ALL."

  Examples:  ADD SYSTEMS/NODE=DARBY
             ADD SYSTEMS/NODE=("DARBY","DOOLEY","ALICAT","ALL")

3.2.1.4    /TYPE

  Specifies the type of system to be added to the display. Systems of
  the specified type are assumed to be removed from the display via the
  REMOVE SYSTEMS/TYPE command.  The type can be any of the valid system
  types as displayed in the HW_TYPE field prior to their removal. If the
  string which specifies the system type contains spaces, slashes or
  hyphens, then the string must be delimited by double quotation marks.
  If /TYPE=ALL is specified, then all nodes are added to the display.

  Format:  ADD SYSTEMS/TYPE=(system-type,"system-type"[,...])
           ADD SYSTEMS/TYPE=ALL

  If only one system type is specified, the parenthesis can be omitted.

  Examples:  ADD SYSTEMS/TYPE="VAX 8650"
             ADD SYSTEMS/TYPE=(HS90,"VAX 8800")

3.3  –  MEMBERS

  Adds the Members class to the display.

  Format:  ADD MEMBERS

3.3.1  –  Qualifiers

3.3.1.1    /ALL

  Adds all the fields in the Members class to the display.

  Format:  ADD MEMBERS/ALL

3.4  –  CIRCUITS

  Adds the Circuits class to the display.  Optionally, circuits
  which are in a particular state can be added to the display.
  By default all circuits are displayed.

  Format:  ADD CIRCUITS [/qualifier,...]

3.4.1  –  Qualifiers

3.4.1.1    /ALL

  Adds all the fields in the Circuits class to the display.

  Format:  ADD CIRCUITS/ALL

3.4.1.2    /TYPE

  Specifies the type of circuits to add to the display.  Valid circuit
  types are:

         OPEN    - Circuits in the open state.
         NOOPEN  - Circuits in the closed state or any of the
                   open-in-progress or close-in progress states.
         ALL     - All types of circuits.

  Format:  ADD CIRCUITS/TYPE=(type[,...])

  If only one type is specified, the parenthesis can be omitted.

3.5  –  CONNECTIONS

  Adds the Connections class to the display.  Optionally,
  connections in a particular state, or connections of a
  particular name can be added to the display.
  By default, all connections are displayed.

  Format:  ADD CONNECTIONS [/qualifier,...]

3.5.1  –  Qualifiers

3.5.1.1    /ALL

  Adds all the fields in the Connections class to the display.

  Format:

          ADD CONNECTIONS/ALL

3.5.1.2    /NAME

  Specifies the local process names of connections that are to be added
  to the display. /NAME can specify the local process name of a
  connection that was previously removed from the display via the REMOVE
  CONNECTION/NAME command or ALL to restore all connections.

  Up to 16 characters of the local process name can be specified.
  If abbreviated, all connections with local process names matching
  the characters specified will be added to the display.

  Format:  ADD CONNECTIONS/NAME=(local-process-name[,...])
           ADD CONNECTIONS/NAME=ALL

  If only one name is specified, the parenthesis can be omitted.

  Examples: ADD CONNECTIONS/NAME=(VMS$DISK_CL_DRVR,VMS$TAPE_CL_DRVR)
            ADD CONNECTIONS/NAME=VMS$

3.5.1.3    /TYPE

  Specifies the type of connections to add to the display.  Valid
  connection types are:

   OPEN    - Connections in the open state.
   NOOPEN  - Connections in the closed state, listen states, or any of
             the connect, disconnect, accept, reject, or failed states.
   ALL     - All types of connections.

  Format:  ADD CONNECTIONS/TYPE=(type[,...])

  If only one type is specified, the parenthesis can be omitted.

3.6  –  COUNTERS

  Adds the Counters class to the display.

  Format:

         ADD COUNTERS

3.6.1  –  Qualifiers

3.6.1.1    /ALL

  Adds all the fields in the Counters class to the display.

  Format:

          ADD COUNTERS/ALL

3.7  –  CREDITS

  Adds the Credits class to the display.

  Format:

         ADD CREDITS

3.7.1  –  Qualifiers

3.7.1.1    /ALL

  Adds all the fields in the Credits class to the display.

  Format:

          ADD CREDITS/ALL

3.8  –  LOCAL_PORTS

  Adds the Local Ports class to the display.

  Format:

         ADD LOCAL_PORTS

3.8.1  –  Qualifiers

3.8.1.1    /ALL

  Adds all the fields in the Local_Ports class to the display.

  Format:

          ADD LOCAL_PORTS/ALL

3.9  –  ERRORS

  Adds the Errors class to the display.

  Format:

         ADD ERRORS

3.9.1  –  Qualifiers

3.9.1.1    /ALL

  Adds all the fields in the Errors class to the display.

  Format:

          ADD ERRORS/ALL
Close Help