NCLHELP.HLB  —  test  mop  client
    Initiates an XID test between the node specified and the node
    specified by the client.

    test  [node node-id] mop client client-name [optional arguments...]

    The Address and Circuit information is required.  If that
    information is not specified in the MOP client database, then it
    must be supplied in the command:

    test [node node-id] mop client client-name -
            circuit circuit-name, -
            address lan-address  [,optional arguments...]

    The optional arguments for the test command are:  count, format,
    length, and sap.

    Examples:

    test mop client lamchp     ! Client gives the Address and Circuit

    test mop client lamchp -   ! Client gives default Circuit
          address 08-00-2b-45-77-ED

    The test requester function must be enabled on the MOP Circuit
    to perform the test operation.  You may enable this function
    using:

    enable mop circuit circuit-name function {test requester}

1  –  SAP

    The optional SAP argument specifies the Service Access Point on
    the target system to which the XID message is to be sent.  SAP is
    an octet (00-FF).  The default SAP is 00.

    test  [node node-id] mop client client-name -
          sap octet [,optional arguments...]

    If an Address and Circuit are not supplied by the MOP client
    database, then that information must be provided in the command:

    test  [node node-id] mop client client-name -
          circuit circuit-name, -
          address lan-address, -
          sap octet [,optional arguments...]

    Examples:

    test mop client lamchp sap ff

    test mop client lamchp circuit fddi-1, -
           address AA-00-04-00-34-56, sap 55

2  –  address

    Address of the node to receive the XID test message.

    test  [node node-id] mop client client-name -
            address lan-address [,optional arguments...]

    The Address and Circuit information is required.  If they are not
    specified in the MOP Client database, that information must be
    included in the command.

3  –  circuit

    Circuit over which the XID test message is to be sent.

    test [node node-id] mop client client-name -
          circuit circuit-name [,optional arguments...]

    The Address and Circuit information is required.  If they are not
    specified in the MOP Client database, that information must be
    included in the command.

4  –  count

    The optional Count argument is an integer between
    0-4294967295 which specifies the number of messages to be tested.
    The default count is 1.

    test  [node node-id] mop client client-name -
          count integer [,optional arguments...]

    If an Address and Circuit are not supplied by the MOP client
    database, then that information must be provided in the command:

    test  [node node-id] mop client client-name -
          circuit circuit-name, -
          address lan-address, -
          count integer [,optional arguments...]

    Examples:

    test mop client lamchp count 50

    test mop client lamchp, circuit fddi-1, -
             address aa-00-04-00-34-56, count 10

5  –  format

    The optional Format argument is an octet (00-FF) which specifies
    the value of each byte in the test data.  The default results in
    alternating 0 and 1 bits (55).

    test [node node-id] mop client client-name -
         format octet [,optional arguments...]

    If an Address and Circuit are not supplied by the MOP client
    database, then that information must be provided in the command:

    test [node node-id] mop client client-name -
         circuit circuit-name, -
         address lan-address, -
         format octet [,optional arguments...]

    Examples:

    test mop client lamchp -    ! Client gives Address and Circuit
         format FF

    test mop client lamchp, -   ! Client gives default Circuit
         address aa-00-04-00-34-56, format 00

6  –  length

    The optional Length argument specifies the length of the test
    data part of each message. The maximum and minimum permitted
    values depend on the particular data link in use.  The range is
    0-4294967295.  The default length is 40.

    test [node node-id] mop client client-name -
         length integer [,optional arguments...]

    If an Address and Circuit are not supplied by the MOP client
    database, then that information must be provided in the command:

    test [node node-id] mop client client-name -
         circuit circuit-name, -
         address lan-address, -
         length integer [,optional arguments...]

    Examples:

    test mop client lamchp -     ! Client gives Address and Circuit
         length 20

    test mop client lamchp -       ! Client gives default Address
         circuit fddi-1, length 45

7  –  Exception Messages

 o  data link error

    An error was reported by the Data Link layer.  Ascertain that
    the query requester function is enabled on the MOP circuit.

 o  unrecognized client

    There is no client with the specified identification.

 o  unrecognized circuit

    There is no circuit with the specified identification.

 o  timeout

    Operation has timed out on the loop command.

 o  entity class not supported (OpenVMS)

    MOP is not registered with EMAA.  The NET$MOP process is
    probably not started.  For instructions on how to restart
    the MOP process, refer to HELP NETWORK_MANAGEMENT MOP.
Close Help