/OPTION_FILE[=file-spec] /NOOPTION_FILE (default) CLBUILD can optionally produce a command option file that contains correct table sizes to hold the command definitions which were just compiled (plus a little room for growth). The /OPTION_FILE qualifier causes this file to be read as input and a new such option file created as output. If /OPTION_FILE is specified with no value, then the file written will have the same name as the input command definition file, but with the file extension .COP; for instance, if the file PMDF_COM:PMDF.CLD was the input parameter, then the default name for the output command option file would be PMDF_COM:PMDF.COP. If the /NOOPTION_FILE qualifier is specified (the default), then no option file will be output. Note that use of the /MAXIMUM qualifier causes CLBUILD to read options from MAXIMUM_COMMAND.DAT in addition to any command option file. This file specifies near maximum table sizes. Only use this qualifier if the current table sizes are inadequate, and only use it to create a new command option file. The /NOIMAGE qualifier should always be specified when /MAXIMUM is specified since a maximum-size image would be truly enormous and extremely wasteful.