It is used by mrd_ready_inport(3mrd). This command is used by the TL820 family of DLT libraries to enable the button on the I/O device (IOD) which opens the Inport door. The robot_info argument is the address of a robot_info_t that has been opened by mrd_startup(3mrd). The port argument is the absolute address of the port to be readied. On supported TL820 configurations which use a left mounted IOD this will always be 64. This routine uses the dev_status_t structure for handing errors. The dev_status_t structure includes the code, os_status, and SCSI error fields. The following describes how to decode errors with the dev_status_t structure. SCSI Errors SCSI errors are indicated when the value of the valid field of the SCSI error is not equal to 0. The key, asc, and ascq fields provide additional information to help determine the cause of the error. The code usually maps the Additional Sense Code and Additional Sense Code Qualifier (ASC/ASCQ) values to an MRD error. The asc and ascq values are copied from the request sense data returned by the target. The Additional Sense Code (asc) indicates further information related to the error or exception condition reported in the sense key field. The Additional Sense Code Qualifier (ascq) indicates detailed information related to the additional sense code. For more information, consult the SCSI-2 Specification. Operating System Errors Operating system errors are indicated when the value of the valid field of the SCSI error is equal to 0 and the value of the os_ status field is not equal to 0. This result is most likely caused by an operating system error, and probably has a mapped error in MRD. MRD Errors MRD errors are indicated when the value of the os_status field is 0, and the value of the valid field of the SCSI error is 0. This result is most likely caused when MRD encounters its own failure.