HELPLIB.HLB  —  START  /QUEUE
    Starts or restarts the specified queue after it has been
    initialized. You also can use this command to change the options
    of the specified queue. The /QUEUE qualifier is required.

    Requires manage (M) access to the queue.

    Format

      START/QUEUE  queue-name[:]

1  –  Parameter

 queue-name[:]

    Specifies the name of the queue to be started or restarted.

2  –  Qualifiers

2.1    /ALIGN

       /ALIGN[=(option[,...])]

    Prints alignment pages to aid in aligning printer forms. Use this
    qualifier only when restarting an output execution queue from a
    paused state.

    After the alignment is complete, the queue enters a paused state
    until you restart it by reentering the START/QUEUE command.
    Printing resumes from the point where alignment data started;
    that is, the task is backspaced over the pages printed for
    alignment.

    Possible options are as follows:

    MASK    Specifies that input data is masked by replacing
            alphabetic characters with x's and numbers with 9s;
            nonalphanumeric characters are not masked. Mask
            characters allow you to prevent the printing of sensitive
            information. If you omit the MASK option, data is printed
            unaltered.

    n       Specifies the number of alignment pages to print. The
            value of n can be from 1 to 20. By default, one page of
            alignment data is printed.

2.2    /AUTOSTART_ON

       /AUTOSTART_ON=(node::[device][,...])

    Designates the queue as an autostart execution queue and
    specifies the node, or node and device, on which the queue can
    be located. Both node and device must be specified for output
    queues. For batch queues, only node is applicable.

    In an OpenVMS Cluster, you can specify more than one node (or
    node and device) on which a queue can run, in the preferred order
    in which nodes should claim the queue. This allows the queue
    to fail over to another node if the node on which the queue is
    running leaves the cluster.

    For autostart queues, the START/QUEUE command activates the queue
    for autostart. The queue will begin processing jobs when the
    ENABLE AUTOSTART/QUEUES command is entered for a node on which
    the queue can run.

    This qualifier cannot be used with the /ON or /GENERIC qualifier;
    however, you can specify the /AUTOSTART_ON qualifier for a queue
    previously created or started with the /ON qualifier. Doing so
    overrides the /ON option and makes the queue an autostart queue.

    For more information about autostart queues, see the chapter
    about managing queues in the VSI OpenVMS System Manager's Manual.

2.3    /BACKWARD

       /BACKWARD=n

    Restarts a print queue n pages before the current page; n
    defaults to 1. If you omit the page value, printing resumes
    at the top of the current page. Use this qualifier only when
    restarting an output execution queue from a paused state.

                                   NOTE

       Using the START/QUEUE/BACKWARD=n command to restart a print
       job that uses Fortran carriage control and that was printed
       with the /NOFEED qualifier can have unexpected results, in
       particular:

       o  The page positioning in the restarted job may not be
          correct: the output may not begin at the top of the page
          specified by n.

       o  The output from the print job may be preceded by extra
          meaningless information.

2.4    /BASE_PRIORITY

       /BASE_PRIORITY=n

    Specifies the base process priority at which jobs are initiated
    from a batch execution queue. By default, if you omit the
    qualifier, jobs are initiated at the same priority as the base
    priority established by DEFPRI at system generation (usually 4).
    The base priority specifier can be any decimal value from 0 to
    15.

2.5    /BLOCK_LIMIT

       /BLOCK_LIMIT=([lowlim,]uplim)
       /NOBLOCK_LIMIT

    Limits the size of print jobs that can be processed on an output
    execution queue. This qualifier allows you to reserve certain
    printers for certain size jobs. You must specify at least one of
    the parameters.

    The lowlim parameter is a decimal number referring to the minimum
    number of blocks that are accepted by the queue for a print job.
    If a print job is submitted that contains fewer blocks than the
    lowlim value, the job remains pending until the block limit for
    the queue is changed. After the block limit for the queue is
    decreased sufficiently, the job is processed.

    The uplim parameter is a decimal number referring to the maximum
    number of blocks that are accepted by the queue for a print job.
    If a print job is submitted that exceeds this value, the job
    remains pending until the block limit for the queue is changed.
    After the block limit for the queue is increased sufficiently,
    the job is processed.

    If you specify only an upper limit for jobs, you can omit the
    parentheses. For example, /BLOCK_LIMIT=1000 means that only jobs
    with 1000 blocks or less are processed in the queue. To specify
    only a lower job limit, you must use a null string ("")  to
    indicate the upper specifier. For example, /BLOCK_LIMIT=(500,"")
    means any job with 500 or more blocks is processed in the queue.
    You can specify both a lower and upper limit. For example,
    /BLOCK_LIMIT=(200,2000) means that jobs with less than 200 blocks
    or more than 2000 blocks are not processed in the queue.

    The /NOBLOCK_LIMIT qualifier cancels the previous setting
    established by the /BLOCK_LIMIT qualifier for the queue.

2.6    /CHARACTERISTICS

       /CHARACTERISTICS=(characteristic[,...])
       /NOCHARACTERISTICS

    Specifies one or more characteristics for processing jobs
    on an execution queue. If a queue does not have all the
    characteristics that have been specified for a job, the job
    remains pending. If you specify only one characteristic, you can
    omit the parentheses. Each time you specify the /CHARACTERISTICS
    qualifier, all previously set characteristics are canceled. Only
    the characteristics specified with the qualifier are established
    for the queue.

    Queue characteristics are installation specific. The
    characteristic parameter can be either a value from 0 to
    127 or a characteristic name that has been defined by the
    DEFINE/CHARACTERISTIC command.

    The /NOCHARACTERISTICS qualifier cancels any settings previously
    established by the /CHARACTERISTICS qualifier for the queue.

2.7    /CLOSE

    Prevents jobs from being entered in the queue through PRINT or
    SUBMIT commands or as a result of requeue operations. To allow
    jobs to be entered, use the /OPEN qualifier. Whether a queue
    accepts or rejects new job entries is independent of the queue's
    state (such as paused, stopped, or stalled). When a queue is
    marked closed, jobs executing continue to execute. Jobs already
    pending in the queue continue to be candidates for execution.

2.8    /CPUDEFAULT

       /CPUDEFAULT=time

    Defines the default CPU time limit for jobs in this batch
    execution queue. You can specify time as delta time, 0, INFINITE,
    or NONE. You can specify up to 497 days of delta time.

    If the queue does not have a specified CPUMAXIMUM time limit and
    the value established in the user authorization file (UAF) has
    a specified CPU time limit of NONE, either the value 0 or the
    keyword INFINITE allows unlimited CPU time. If you specify NONE,
    the CPU time value defaults to the value specified either in the
    UAF or by the SUBMIT command (if included). CPU time values must
    be greater than or equal to the number specified by the system
    parameter PQL_MCPULM.

    For information on specifying delta times, see the OpenVMS User's
    Manual or the online help topic Date.

2.9    /CPUMAXIMUM

       /CPUMAXIMUM=time

    Defines the default CPU time limit for all jobs in this batch
    execution queue. You can specify time as delta time, 0, INFINITE,
    or NONE. You can specify up to 497 days of delta time.

    If the queue does not have a specified CPUMAXIMUM time limit
    and the value established in the UAF has a specified CPU time
    limit of NONE, either the value 0 or the keyword INFINITE allows
    unlimited CPU time. If you specify NONE, the CPU time value
    defaults to the value specified either in the UAF or by the
    SUBMIT command (if included). CPU time values must be greater
    than or equal to the number specified by the system parameter
    PQL_MCPULM. The time cannot exceed the CPU time limit set by the
    /CPUMAXIMUM qualifier. For information on specifying delta time,
    see the OpenVMS User's Manual or the online help topic Date.

2.10    /DEFAULT

       /DEFAULT=(option[,...])
       /NODEFAULT

    Establishes defaults for certain options of the PRINT command.
    Defaults are specified by the list of options. If you specify
    only one option, you can omit the parentheses. After you set an
    option for the queue with the /DEFAULT qualifier, you do not have
    to specify that option in your PRINT commands. If you do specify
    these options in your PRINT command, the values specified with
    the PRINT command override the values established for the queue
    with the /DEFAULT qualifier.

    You cannot use the /DEFAULT qualifier with the /GENERIC
    qualifier.

    Possible options are as follows:

    [NO]BURST[=keyword]    Controls whether two file flag pages with
                           a burst bar between them are printed
                           preceding output. If you specify the
                           value ALL (default), these flag pages
                           are printed before each file in the job.
                           If you specify the value ONE, these flag
                           pages are printed once before the first
                           file in the job.

    [NO]FEED               Specifies whether a form feed is inserted
                           automatically at the end of a page.

    [NO]FLAG[=keyword]     Controls whether a file flag page is
                           printed preceding output. If you specify
                           the value ALL (default), a flag page is
                           printed before each file in the job. If
                           you specify the value ONE, a flag page is
                           printed once before the first file in the
                           job.

    FORM=type              Specifies the default form for an output
                           execution queue. If a job is submitted
                           without an explicit form definition, this
                           form is used to process the job. If no
                           form type is explicitly specified with
                           the FORM keyword, the system assigns the
                           form "DEFAULT" to the queue. See also
                           the description of the /FORM_MOUNTED
                           qualifier.

    [NO]TRAILER[=keyword]  Controls whether a file trailer page is
                           printed following output. If you specify
                           the value ALL (default), a trailer page
                           is printed after each file in the job. If
                           you specify the value ONE, a trailer page
                           is printed once after the last file in the
                           job.

    When you specify the BURST option for a file, the [NO]FLAG option
    does not add or subtract a flag page from the two flag pages that
    are printed preceding the file. For information on establishing
    mandatory queue options, see the description of the /SEPARATE
    qualifier. For more information on specifying default queue
    options, see the VSI OpenVMS System Manager's Manual.

2.11    /DESCRIPTION

       /DESCRIPTION=string
       /NODESCRIPTION

    Specifies a string of up to 255 characters that is used to
    provide operator-supplied information about the queue.

    Enclose strings containing lowercase letters, blanks, or other
    nonalphanumeric characters (including spaces) in quotation marks
    (" ").

    The /NODESCRIPTION qualifier removes any descriptive text that
    may be associated with the queue.

2.12    /DISABLE_SWAPPING

       /DISABLE_SWAPPING
       /NODISABLE_SWAPPING

    Controls whether batch jobs executed from a queue can be swapped
    in and out of memory.

2.13    /ENABLE_GENERIC

       /ENABLE_GENERIC
       /NOENABLE_GENERIC

    Specifies whether files queued to a generic queue that does
    not specify explicit queue names with the /GENERIC qualifier
    can be placed in this execution queue for processing. For more
    information, see the description of the /GENERIC qualifier.

2.14    /FORM_MOUNTED

       /FORM_MOUNTED=type

    Specifies the mounted form for an output execution queue.

    If no form type is explicitly specified, the system assigns the
    form "DEFAULT" to the queue.

    If the stock of the mounted form does not match the stock of the
    default form, as indicated by the /DEFAULT=FORM qualifier, all
    jobs submitted to this queue without an explicit form definition
    enter a pending state and remain pending until the stock of the
    mounted form of the queue is identical to the stock of the form
    associated with the job.

    If a job is submitted with an explicit form and the stock of the
    explicit form is not identical to the stock of the mounted form,
    the job enters a pending state and remains pending until the
    stock of the mounted form of the queue is identical to the stock
    of the form associated with the job.

    To specify the form type, use either a numeric value or a form
    name that has been defined by the DEFINE/FORM command. Form
    types are installation-specific. You cannot use the /FORM_MOUNTED
    qualifier with the /GENERIC qualifier.

2.15    /FORWARD

       /FORWARD=n

    Advances the specified number of pages before resuming printing
    the current file in the current job; the default is 1. If you
    omit the page value, printing resumes at the top of the next
    page. Use this qualifier only when restarting an output execution
    queue from a paused state.

2.16    /GENERIC

       /GENERIC[=(queue-name[,...])]
       /NOGENERIC

    Specifies a generic queue. Also specifies that jobs placed in
    this queue can be moved for processing to compatible execution
    queues. The /GENERIC qualifier optionally accepts a list of
    target execution queues that have been previously defined. For a
    generic batch queue, these target queues must be batch execution
    queues. For a generic output queue, these target queues must be
    output execution queues, but can be of any type (printer, server,
    or terminal). For example, a generic printer queue can feed a
    mixture of printer and terminal execution queues.

    Use the /GENERIC qualifier to change the list of target nodes
    for a generic queue. The queue must have been initialized as a
    generic queue with the INITIALIZE/QUEUE/GENERIC command.

    If you do not specify any target execution queues with the
    /GENERIC qualifier, jobs can be moved to any execution queue
    that (1)  is initialized with the /ENABLE_GENERIC qualifier, and
    (2)  is the same type (batch or output) as the generic queue.

    To define the queue as a generic batch or output queue, you use
    the /GENERIC qualifier with either the /BATCH or the /DEVICE
    qualifier. If you specify neither the /BATCH nor the /DEVICE
    qualifier on creation of a generic queue, by default the queue
    becomes a generic printer queue.

2.17    /JOB_LIMIT

       /JOB_LIMIT=n

    Specifies the number of batch jobs that can be executed
    concurrently from the queue. Specify a number in the range 0
    to 255.

2.18    /LIBRARY

       /LIBRARY=filename
       /NOLIBRARY

    Specifies the file name for the device control library. When you
    initialize an output execution queue, you can use the /LIBRARY
    qualifier to specify an alternate device control library. You can
    use only a file name as the parameter of the /LIBRARY qualifier.
    The system always assumes that the file is located in SYS$LIBRARY
    and that the file type is .TLB.

2.19    /NEXT

    Aborts the currently suspended print job and begins processing of
    the first pending job in the queue. Use this qualifier only when
    restarting an output execution queue from a paused state.

2.20    /NO_INITIAL_FF

       /NO_INITIAL_FF
       /NONO_INITIAL_FF (default)

    Specifies whether a form feed should be sent to a printer device
    when a queue starts. To suppress the initial form feed, use the
    /NO_INITIAL_FF qualifier.

    The /NONO_INITIAL_FF qualifier sends a form feed to the output
    device to ensure that the paper is at the top of a page before
    printing begins.

2.21    /ON

       /ON=[node::]device[:] (printer, terminal, server queue)
       /ON=node:: (batch queue)

    Specifies the node or device, or both, on which this execution
    queue is located. For batch execution queues, you can specify
    only the node name. For output execution queues, you can include
    both the node name and the device name.

    The node name is used only in VAXcluster systems; it must match
    the node name specified by the system parameter SCSNODE for the
    VAX computer on which the queue executes.

    You cannot use the /ON qualifier with the /AUTOSTART_ON or
    /GENERIC qualifier; however, you can specify the /ON qualifier
    for a queue previously created or started with the /AUTOSTART_ON
    qualifier. Doing so overrides the /AUTOSTART_ON qualifier and
    makes the queue a nonautostart queue.

2.22    /OPEN

    Allows jobs to be entered in the queue through PRINT or SUBMIT
    commands or as the result of requeue operations. To prevent
    jobs from being entered in the queue, use the /CLOSE qualifier.
    Whether a queue accepts or rejects new job entries is independent
    of the queue's state (such as paused, stopped, or stalled).

2.23    /OWNER_UIC

       /OWNER_UIC=uic

    Requires manage (M) access to the queue.

    Enables you to change the user identification code (UIC) of the
    queue. Specify the UIC by using standard format as described in
    the OpenVMS User's Manual.

2.24    /PROCESSOR

       /PROCESSOR=filename
       /NOPROCESSOR

    Requires OPER (operator) privilege to change the file name from
    the one with which the queue was initialized.

    Allows you to specify your own print symbiont for an output
    execution queue. You can use any valid file name as a parameter
    of the /PROCESSOR qualifier. The system supplies the device and
    directory name SYS$SYSTEM and the file type .EXE. If you use this
    qualifier for an output queue, it specifies that the symbiont
    image to be executed is SYS$SYSTEM:filename.EXE.

    By default, SYS$SYSTEM:PRTSMB.EXE is the symbiont image
    associated with an output execution queue.

    The /NOPROCESSOR qualifier cancels any previous setting
    established by the /PROCESSOR qualifier, and causes
    SYS$SYSTEM:PRTSMB.EXE to be used.

2.25    /PROTECTION

       /PROTECTION=(ownership[:access],...)

    Requires OPER (operator) privilege, or control (C)  and execute
    (E)  access to the queue.

    Specifies the protection of the queue.

    o  Specify the ownership parameter as system (S),  owner (O),
       group (G),  or world (W).

    o  Specify the access parameter as read (R),  submit (S), manage
       (M),  or delete (D). A null access specification means no
       access.

    If you include only one protection code, you can omit the
    parentheses.

    For more information on specifying protection codes, see the
    VSI OpenVMS Guide to System Security. For more information on
    controlling queue operations through UIC-based protection, see
    the VSI OpenVMS System Manager's Manual.

2.26    /RAD

       /RAD=n

    Specifies the RAD number on which to run batch jobs assigned
    to the queue. The RAD value is validated as a positive integer
    between 0 and the value returned by the $GETSYI item code, SYI$_
    RAD_MAX_RADS.

    RAD is supported on AlphaServer GS series systems and starting
    from OpenVMS Version 8.4, support is extended to NUMA capable
    Integrity servers.

2.27    /RECORD_BLOCKING

       /RECORD_BLOCKING
       /NORECORD_BLOCKING

    Determines whether the symbiont can concatenate (or block
    together) output records for transmission to the output device.
    If you specify the /NORECORD_BLOCKING qualifier, the symbiont
    sends each formatted record in a separate I/O request to the
    output device. For the standard OpenVMS print symbiont, record
    blocking can have a significant performance advantage over
    single-record mode.

2.28    /RETAIN

       /RETAIN[=option]
       /NORETAIN

    Holds jobs in the queue in a retained status after they have
    executed. The /NORETAIN qualifier enables you to reset the queue
    to the default. Possible options are as follows:

    ALL     Holds all jobs in the queue after execution.
    ERROR   Holds in the queue only jobs that fail to complete.

    A user can request a job retention option for a job by specifying
    the /RETAIN qualifier with the PRINT, SUBMIT, or SET ENTRY
    command. However, the job retention option you specify for a
    queue overrides any job retention option requested by a user for
    a job in that queue.

2.29    /SCHEDULE

       /SCHEDULE=[NO]SIZE

    Specifies whether pending jobs in an output queue are
    scheduled for printing based on the size of the job. When the
    /SCHEDULE=SIZE qualifier is in effect, shorter jobs are printed
    before longer ones. When the /SCHEDULE=NOSIZE qualifier is
    in effect, jobs are printed in the order they were submitted,
    regardless of size.

    If you enter this command while there are pending jobs in any
    queue, its effect on future jobs is unpredictable.

2.30    /SEARCH

       /SEARCH="search-string"

    Specifies that printing is to resume at the page containing
    the specified string. The search for the string moves forward,
    beginning on the page following the current page. During the
    search, consecutive tabs and spaces are treated as a single
    space, and character case is ignored. The string can be from 1
    to 63 characters and must be enclosed in quotation marks (" ").
    Use this qualifier only when restarting an output execution queue
    from a paused state.

2.31    /SEPARATE

       /SEPARATE=(option[,...])
       /NOSEPARATE

    Specifies the mandatory queue options, or job separation options,
    for an output execution queue. Job separation options cannot be
    overridden by the PRINT command.

    You cannot use the /SEPARATE qualifier with the /GENERIC
    qualifier.

    The job separation options are as follows:

    [NO]BURST               Specifies whether two job flag pages with
                            a burst bar between them are printed at
                            the beginning of each job.

    [NO]FLAG                Specifies whether a job flag page is
                            printed at the beginning of each job.

    [NO]TRAILER             Specifies whether a job trailer page is
                            printed at the end of each job.

    [NO]RESET=(module[,...])Specifies one or more device control
                            library modules that contain the job
                            reset sequence for the queue. The
                            specified modules from the queue's
                            device control library (by default
                            SYS$LIBRARY:SYSDEVCTL) are used to reset
                            the device each time a job reset occurs.
                            The RESET sequence occurs after any file
                            trailer and before any job trailer. Thus,
                            all job separation pages are printed when
                            the device is in its RESET state.

    When you specify /SEPARATE=BURST, the [NO]FLAG separation option
    does not add or subtract a flag page from the two flag pages that
    are printed preceding the job.

    For information on establishing queue options that can be
    overridden, see the description of the /DEFAULT qualifier.

    For more information on specifying mandatory queue options, see
    the VSI OpenVMS System Manager's Manual.

2.32    /TOP_OF_FILE

    Resumes printing at the beginning of the file that was current
    when the output execution queue paused. Use this qualifier only
    when restarting an output execution queue from a paused state.

2.33    /WSDEFAULT

       /WSDEFAULT=n

    Defines for a batch job a working set default, the default number
    of physical pages that the job can use. The value set by this
    qualifier overrides the value defined in the user authorization
    file (UAF) of any user submitting a job to the queue.

    You also can specify this qualifier for an output execution
    queue. Used in this context, the /WSDEFAULT qualifier establishes
    the working set default of the symbiont process for an execution
    queue when the symbiont process is created.

    Specify the value of n as a number of 512-byte pagelets on Alpha.
    Note that the operating systems rounds up this value to the
    nearest CPU-specific page so that the actual amount of physical
    memory allowed may be larger than the specified amount on Alpha.

    If you specify the value 0 or NONE, the working set default
    value defaults to the value specified in the UAF or by the SUBMIT
    command (if included).

2.34    /WSEXTENT

       /WSEXTENT=n

    Defines for the batch job a working set extent, the maximum
    amount of physical memory that the job can use. The job uses
    the maximum amount of physical memory only when the system has
    excess free pages. The value set by this qualifier overrides the
    value defined in the user authorization file (UAF) of any user
    submitting a job to the queue.

    You also can specify this qualifier for an output execution
    queue. Used in this context, the /WSEXTENT qualifier establishes
    the working set extent of the symbiont process for an output
    execution queue when the symbiont process is created.

    Specify the value of n as a number of 512-byte pagelets on
    Alpha. Note that the operating system rounds up this value to the
    nearest CPU-specific page so that the actual amount of physical
    memory allowed may be larger than the specified amount on Alpha.

    If you specify the value 0 or NONE, the working set extent value
    defaults to the value specified in the UAF or by the SUBMIT
    command (if included).

2.35    /WSQUOTA

       /WSQUOTA=n

    Defines for a batch job a working set quota, the amount of
    physical memory that is guaranteed to the job. The value set
    by this qualifier overrides the value defined in the user
    authorization file (UAF) of any user submitting a job to the
    queue.

    You also can specify this qualifier for an output execution
    queue. Used in this context, the /WSQUOTA qualifier establishes
    the working set quota of the symbiont process for an output
    execution queue when the symbiont process is created.

    Specify the value of n as a number of 512-byte pagelets on
    Alpha. Note that the operating system rounds up this value to the
    nearest CPU-specific page so that the actual amount of physical
    memory allowed may be larger than the specified amount on Alpha.

    If you specify the value 0 or NONE, the working set quota value
    defaults to the value specified in the UAF or by the SUBMIT
    command (if included).

    Working set default, working set quota, and working set extent
    values are included in each user record in the system UAF. You
    can specify working set values for individual jobs or for all
    jobs in a given queue. The decision table shows the action taken
    for different combinations of specifications that involve working
    set size and working set quota values.

    Value Specified  Value
    by               Specified
    the SUBMIT       for the
    Command?         Queue?          Action Taken

    No               No              Use the UAF value.

    No               Yes             Use value for the queue.

    Yes              Yes             Use smaller of the two values.

    Yes              No              Compare specified value with UAF
                                     value; use the smaller.

3  –  Examples

    1.$ STOP/QUEUE  LPA0
      $ START/QUEUE/TOP_OF_FILE  LPA0

      The STOP/QUEUE command in this example suspends the job that is
      currently executing on the printer queue LPA0 and places that
      queue in the paused state. The START/QUEUE command releases the
      queue from the paused state. The /TOP_OF_FILE qualifier causes
      the job that was suspended to resume printing at the beginning
      of the file rather than at where it was interrupted.

    2.$ INITIALIZE/QUEUE  LPA0
         .
         .
         .
      $ START/QUEUE/DEFAULT=FLAG  LPA0

      The INITIALIZE/QUEUE command in this example initializes the
      queue named LPA0. Later, the START/QUEUE command starts the
      queue. The /DEFAULT qualifier requests that a flag page precede
      each file in each job.

    3.$ START/QUEUE/DEFAULT=FORM=LN01_PORTRAIT LN01_PRINT

      The START/QUEUE command in this example restarts the LN01_PRINT
      queue with the default form LN01_PORTRAIT.

    4.$ INITIALIZE/QUEUE/START/GENERIC=(A,B)  MYQUEUE
      .
      .  [new printers X and Y are brought in at a later date]
      .
      $ STOP/QUEUE/NEXT MYQUEUE
      $ START/QUEUE/GENERIC=(X,Y) MYQUEUE

      This example changes the list of target nodes for a generic
      queue. Note that the queue was previously initialized as a
      generic queue.

    5.$ START/QUEUE/RAD=1 BATCHQ1

      $ SHOW QUEUE/FULL BATCHQ1
      Batch queue BATCHQ1, idle, on QUEBID::
       /BASE_PRIORITY=4 /JOB_LIMIT=3 /OWNER=[SYSTEM]
       /PROTECTION=(S:M,O:D,G:R,W:S) /RAD=1

      This example modifies BATCHQ1 to run all assigned jobs on RAD 1
      of QUEBID, and readies the queue to accept jobs for processing.

4    /MANAGER

    Starts the clusterwide queue manager for the queuing system
    and opens that queue manager's queue database files. The /QUEUE
    qualifier is optional, but the /MANAGER qualifier is required.

    By default, the command affects the default queue manager,
    SYS$QUEUE_MANAGER. Specify the /NAME_OF_MANAGER qualifier
    to start a queue manager other than the default. For more
    information, see the VSI OpenVMS System Manager's Manual.

    Requires OPER (operator) and SYSNAM (system logical name)
    privileges.

    Format

      START/QUEUE/MANAGER  [dirspec]

4.1  –  Parameter

 dirspec

    Specifies the directory location to contain the system queue and
    journal files of the queue database. The queue file has a file
    type of QMAN$QUEUES and contains queue definitions. The journal
    file has a file type of QMAN$JOURNAL and contains job and other
    information that lets the queue manager to return to its last
    known state should a system be stopped unexpectedly. These files
    must reside in the same directory.

    The default location of the queue and journal files is
    SYS$COMMON:[SYSEXE]. The optional dirspec parameter is used
    only for specifying an alternate location for the queue and
    journal files. The specification must include at least the
    device and directory name. The asterisk (*)  and the percent
    sign (%)  wildcard characters are not allowed in the directory
    specification.

    The directory you specify must be available to all nodes that
    can run the queue manager. If the directory specification is a
    concealed logical name, it must be identically defined on all
    nodes in the cluster.

    The location of the queue and journal files is stored in the
    master file of the queue database. You do not have to respecify
    the directory location with subsequent START/QUEUE/MANAGER
    commands.

    For information about changing the location of any of the queue
    database files, see the Guide to Maintaining a VMS System.

4.2  –  Description

    The START/QUEUE/MANAGER command has the following uses:

    o  Enter the command START/QUEUE/MANAGER/NEW_VERSION to create
       the queue database and initially start a queue manager.
       See the description of the /NEW_VERSION qualifier for more
       information. Once the queue manager has been started, it
       will remain running unless it is explicitly stopped with the
       STOP/QUEUE/MANAGER/CLUSTER command.

    o  If the STOP/QUEUE/MANAGER/CLUSTER command has been executed,
       enter the START/QUEUE/MANAGER command to restart a queue
       manager.

    o  In an OpenVMS Cluster, enter the START/QUEUE/MANAGER command
       with the /ON qualifier to modify the list of preferred nodes
       on which a queue manager can run. See the description of the
       /ON qualifier for more information.

    o  In an OpenVMS Cluster, enter the START/QUEUE/MANAGER command
       to ensure that a queue manager process is executing on the
       most preferred, available node. If the queue manager is not
       running on the most preferred, available node, the queue
       manager will be moved to that node without interruption of
       service. If you are using the default node list (*),  the
       queue manager will not move. For more information, see the
       description of the /ON qualifier.

    If the queue manager is in a location other than the default, and
    in OpenVMS Cluster environments with multiple system disks, you
    must define the logical name QMAN$MASTER. For instructions, see
    the chapter about the queue manager and queue database in the VSI
    OpenVMS System Manager's Manual.

    If a queue manager does not start when you enter the
    START/QUEUE/MANAGER command, you will receive the following
    message:

    %JBC-E-QMANNOTSTARTED, queue manager could not be started

    If you see this message, search the operator log file
    SYS$MANAGER:OPERATOR.LOG (or look on the operator console) for
    messages from the facilities QUEUE_MANAGE and JOB_CONTROL for
    information about the problem, as follows:

    $ SEARCH SYS$MANAGER:OPERATOR.LOG /WINDOW=5 QUEUE_MANAGE,JOB_CONTROL

4.3  –  Qualifiers

4.3.1    /ADD

    Creates an additional queue manager in the existing queue
    database. If the named queue manager already exists, the request
    will be rejected.

4.3.2    /NAME_OF_MANAGER

       /NAME_OF_MANAGER=name

    Creates a non-default queue manager. The required name value may
    be up to 31 characters long and may be a logical. The name will
    serve as the identifier for the queue manager process and the
    portion of the database that it is managing.

4.3.3    /NEW_VERSION

       /NEW_VERSION
       /NONEW_VERSION (default)

    Specifies that a new (empty) version of the queue database is to
    be created. This qualifier is required when initially creating
    and starting the queuing system.

    If you specify this qualifier and a queue database already
    exists, the new master and queue files of the queue database
    supersede existing versions of those files; however, the journal
    file of the existing queue database is deleted. Jobs and other
    information are lost.

4.3.4    /ON

       /ON=(node[,...])

    In an OpenVMS Cluster, specifies the nodes on which a clusterwide
    queue manager can run. The default value for the node list is
    the asterisk (*)  wildcard character, meaning that all nodes in
    the cluster are eligible to run the queue manager. If the node on
    which the queue manager is running leaves the cluster, the queue
    manager can automatically fail over to any available node in the
    cluster. However, to specify a preferred order in which the nodes
    should claim the queue manager, or to limit the nodes which can
    run it, you must specify the /ON qualifier.

    The node list you specify is stored in the queue database.
    Anytime the START/QUEUE/MANAGER command is entered and neither
    the /NEW_VERSION nor /ON qualifier is specified, the /ON list
    stored in the queue database remains unchanged.

    For highest availability, specify the asterisk (*)  wildcard
    character as the last node in the node list to indicate that
    any remaining unlisted node can claim the queue manager, with
    no preferred order. If you do not specify the asterisk (*)
    wildcard character last in the node list, the queue manager can
    only fail over if one of the nodes in the list is available;
    however, if you want to exclude certain nodes from being eligible
    to run the queue manager, you cannot use the asterisk (*)
    wildcard character. You cannot specify the asterisk (*)  wildcard
    character as part of a node name.

    Anytime the START/QUEUE/MANAGER command is entered (with or
    without the /ON qualifier), the job controller will check to
    see if one or more preferred queue manager nodes was currently
    or previously specified with the /ON qualifier. If one or more
    preferred nodes was specified, and the queue manager is running
    on a node other than the first available node of those specified,
    the queue manager process is moved from its current node and
    restarted on the first available preferred node. Despite the
    transition, queues on the running nodes are not stopped. All
    requests to the queuing system, for example, PRINT, SUBMIT, and
    SHOW ENTRY requests, will complete as expected.

4.4  –  Examples

    1.$ START/QUEUE/MANAGER/NEW_VERSION
      $ SHOW QUEUE
      %JBC-E-NOSUCHQUE, no such queue

      The START/QUEUE/MANAGER command in this example starts the
      queue manager and creates the queue and journal files in the
      default location, SYS$COMMON:[SYSEXE]. Because the asterisk
      (*)  wildcard character is used by default as the value for the
      list of nodes on which the queue manager can run, the queue
      manager can fail over to any available node in the cluster.

      This command starts the default queue manager SYS$QUEUE_MANAGER
      because the /NAME_OF_MANAGER qualifier is not specified.

      Both the SYS$COMMON:[SYSEXE] location and the value for the
      /ON qualifier (which is * by default in this example) are
      stored in the queue database for future reference. The newly
      created queue database contains no queues or jobs. The SHOW
      QUEUE command shows that no queues are defined on this cluster.

    2.$ START/QUEUE/MANAGER/NEW_VERSION -
      _$ /ON=(SATURN,VENUS,NEPTUN,*) DUA5:[SYSQUE]

      The START/QUEUE/MANAGER command in this example creates the
      queue and journal files on the cluster-accessible disk volume
      DUA5, in directory SYSQUE. You must mount the disk before you
      enter the START/QUEUE/MANAGER command.

      The /ON qualifier specifies that the queue manager should run
      first on node SATURN. If SATURN leaves the cluster, the queue
      manager will attempt to fail over to VENUS. If VENUS is not
      available, the queue manager will attempt to fail over to
      NEPTUN. If NEPTUN is not available, the queue manager will
      fail over to any other available node in the cluster.

    3.$ START/QUEUE/MANAGER/NEW_VERSION -
      _$ /ON=(SATURN,VENUS,NEPTUN,*) DUA5:[SYSQUE])
         .
         .
         .
      $ START/QUEUE/MANAGER

      The START/QUEUE/MANAGER command in this example creates the
      queue database as shown in the previous example. Suppose the
      queue manager started on node SATURN.

      Later, SATURN is removed from the cluster, and the queue
      manager fails over to node VENUS. When SATURN rejoins the
      cluster, the second START/QUEUE/MANAGER command in the example
      is entered to move the queue manager back to node SATURN.

      The second START/QUEUE/MANAGER command does not specify the
      DUA5:[SYSQUE] parameter value or the /ON qualifier and its node
      list because those previously supplied pieces of information
      are stored in the queue database. The queue manager continues
      to use the queue and journal files found at the location
      stored in its database. The /ON list, stored as a result of the
      previous START/QUEUE/MANAGER command, also remains unchanged.

    4.$ START/QUEUE/MANAGER DUA4:[SYSQUE]
      %JBC-E-QMANNOTSTARTED, queue manager could not be started
      $ SEARCH SYS$MANAGER:OPERATOR.LOG /WINDOW=5 QUEUE_MANAGE,JOB_CONTROL
      %%%%%%%%%%%  OPCOM  14-DEC-2001 18:55:18.23  %%%%%%%%%%%
      Message from user QUEUE_MANAGE on QMUNGR
      %QMAN-E-OPENERR, error opening DUA4:[SYSQUE]SYS$QUEUE_MANAGER.QMAN$QUEUES;

      %%%%%%%%%%%  OPCOM  14-DEC-2001 18:55:18.29  %%%%%%%%%%%
      Message from user QUEUE_MANAGE on QMUNGR
      -RMS-F-DEV, error in device name or inappropriate device type for
 	operation

      %%%%%%%%%%%  OPCOM  14-DEC-2001 18:55:18.31  %%%%%%%%%%%
      Message from user QUEUE_MANAGE on QMUNGR
      -SYSTEM-W-NOSUCHDEV, no such device available
      $ START/QUEUE/MANAGER DUA5:[SYSQUE]

      In this example, the first START/QUEUE/MANAGER command
      specifies device DUA4: as the location of the queue and journal
      files. The error message indicates that the queue manager does
      not start. The SEARCH command searches the operator log file
      for relevant messages, and reveals that device DUA4: does not
      exist. The second START/QUEUE/MANAGER command specifies the
      correct device name, DUA5:.
Close Help