SET(MESSAGE_ACTION_LEVEL) Sets the severity level at which TPU emphasizes completion messages in the manner you specify. Syntax SET (MESSAGE_ACTION_LEVEL, {integer | keyword}) Parameters integer A value between 0 and 3 specifying the severity level at which TPU is to take the action you designate. The default value is 2. The severity levels and corresponding values, in ascending order of severity, are as follows: Value Severity Level ----- -------------- 1 Success 3 Informational 0 Warning 2 Error TPU performs the action you specify on all completion messages at the severity level you designate and on all messages of greater severity. keyword The keyword associated with a TPU completion message. TPU uses the keyword to determine the severity level of the associated completion message and performs the action you specify on all completion messages of that severity level or greater. Examples 1. The following statements directs TPU to display informational, warning, and error messages in reverse video for 1/2 second, then in ordinary video. SET (MESSAGE_ACTION_TYPE, REVERSE); SET (MESSAGE_ACTION_LEVEL, 3); 2. The following statements direct TPU to ring the terminal's bell whenever a completion status occurs with a severity equal to or greater than the severity of TPU$_SUCCESS. SET (MESSAGE_ACTION_TYPE, BELL); SET (MESSAGE_ACTION_LEVEL, TPU$_SUCCESS); Related Topic SET(MESSAGE_ACTION_LEVEL)