/sys$common/syshlp/SYSGEN.HLB  —  Sys Parameters, TTY_DEFCHAR2
    TTY_DEFCHAR2 sets a second longword of default terminal
    characteristics. The default characteristics are represented
    as a code that is derived by summing the following hexadecimal
    values:

    Characteristic Value (Hex)   Function

    LOCALECHO             1      Enable local echo terminal logic;
                                 use with the TTY_DEFCHAR NOECHO
                                 characteristic.
    AUTOBAUD              2      Enable autobaud detection.
    HANGUP                4      Hang up on logout.
    MODHANGUP             8      Allow modification of HANGUP without
                                 privileges.
    BRDCSTMBX            10      Allow sending of broadcasts to
                                 mailboxes.
    XON                  20      (No effect in this parameter.)
    DMA                  40      (No effect in this parameter.)
    ALTYPEAHD            80      Use the alternate type-ahead
                                 parameters.
    SETSPEED            100      Clear to allow setting of speed
                                 without privileges.
    DCL_MAILBX          200      Function reserved for VSI use only.
    DECCRT4             400      Terminal is DIGITAL CRT Level 4.
    COMMSYNC            800      Enable flow control using modem
                                 signals.
    EDITING            1000      Line editing allowed.
    INSERT             2000      Sets default mode for insert.
    FALLBACK           4000      Do not set this bit with SYSGEN.
    DIALUP             8000      Terminal is a dialup line.
    SECURE            10000      Guarantees that no process is
                                 connected to terminal after Break
                                 key is pressed.
    DISCONNECT        20000      Allows terminal disconnect when a
                                 hangup occurs.
    PASTHRU           40000      Terminal is in PASTHRU mode.
    SYSPWD            80000      Log in with system password only.
    SIXEL            100000      Sixel graphics.
    DRCS             200000      Terminal supports loadable character
                                 fonts.
    PRINTER          400000      Terminal has printer port.
    APP_KEYPAD       800000      Notifies application programs of
                                 state to set keypad on exit.
    ANSICRT         1000000      Terminal conforms to ANSI CRT
                                 programming standards.
    REGIS           2000000      Terminal has REGIS CRT capabilities.
    BLOCK           4000000      Block mode terminal.
    AVO             8000000      Terminal has advanced video.
    EDIT           10000000      Terminal has local edit
                                 capabilities.
    DECCRT         20000000      Terminal is a DIGITAL CRT.
    DECCRT2        40000000      Terminal is a DIGITAL CRT Level 2.
    DECCRT3        80000000      Terminal is a DIGITAL CRT Level 3.

    The defaults are AUTOBAUD and EDITING.
Close Help