Library /sys$common/syshlp/PCA$HELP.HLB  —  SET  LOG
    PCA Command

    Specifies that user input and PCA output be recorded in a log
    file.

    Format

      SET LOG  [file-spec]

1  –  Parameters

 file-spec

    Specifies the log file to create. All subsequent PCA input and
    output is recorded in this file until logging is disabled. File-
    spec is any valid OpenVMS file specification. The default file
    type is LOG. An omitted file-spec defaults to PCAC.LOG when you
    are in the Collector, or PCAA.LOG when you are in the Analyzer.

2  –  Description

    The SET LOG command records all PCA input and output in the
    specified log file. Input is recorded as entered. Output is
    recorded with a leading exclamation point (!). Since the
    exclamation point is the PCA comment character, you can rerun the
    logged PCA session by using the log file as a command procedure.

3  –  Examples

  PCAC> SET LOG [PING]PONG

      This command establishes the file [PING]PONG.LOG as the
      Collector log file. All subsequent commands and their output
      are recorded in this file.