     CATCH ALL FILTER
         Default: Pass                         Value: Pass or Block

         Action to take if neither the specific filter nor the global filter
         contains an entry that matches an event.

         PASS  - Report the event.

         BLOCK - Discard the event.

     CONNECT RETRY TIMER
         Default: 120                          Value: 0-65535

         Number of seconds to wait after a disconnect or connection reject
         before reattempting a connection. Connection attempts continue
         until a connection is made or until the connect timer enabled
         attribute is set to false or the Outbound Stream is disabled. If
         the Outbound Stream is already connected to the sink when the
         timer expires, no connection is attempted at that time. The timer
         resets and connection attempts continue whenever the timer expires.

     ENABLE CONNECT TIMER
         Default: True                         Value: True or False

         Specifies whether the connect timer is operational see connect
         retry timer.

     DISCONNECT TIMER
         Default: 0                             Value: 0-4294967295

         Number of seconds to wait before disconnecting an idle connection.
         Zero indicates that there is no disconnect timer and connections
         are never automatically disconnected.

     SINK END USER
         Default: Number=82                     Value: end-user-specification

         Sink session control end user specification for this stream.

     SINK NODE
         Default: Local Node                    Value: Full-name

         Full DNS node name of the sink for this stream. Modifying this
         characteristic affects only subsequent connect requests; existing
         connections are unaffected. This fullname is used in combination
         with the sink end user characteristic to establish the sink
         connection.

     SINK OBJECT
         Default: No Sink Object                 Value: Full-name

        Full DNS object name of the sink for this stream. Modifying this
         characteristic affects only subsequent connect requests; existing
         connections are unaffected. This fullname should match the  object
         name characteristic of the target sink.