1 – BLOCK count
Applies only to X25 lines. Specifies the maximum size in bytes of the frame for the line. This value must be at least 5 bytes larger than the maximum packet size you specify in SET CIRCUIT (for PVCs and DLM circuits) or SET MODULE X25-PROTOCOL (for SVCs). Specify a value in the range 21 to 4103. By default the size of the frame takes the value specified by the PROFILE parameter of the SET MODULE X25-PROTOCOL command.
2 – RETRANSMITS count
Applies only to X25 lines. Specifies the maximum number of retransmissions of a frame on the specified line. Specify a value in the range 1 to 255. By default, the retransmission value takes the network value specified by the NETWORK parameter of the SET MODULE X25-PROTOCOL command.
3 – WINDOW count
Applies only to X25 lines. Specifies the maximum window size allowed for the X25 circuit - that is, the maximum number of packets for which outstanding acknowledgments are allowed. Specify a value in the range 1 to 127. By default window size takes the value specified by the PROFILE parameter of the SET or DEFINE MODULE X25-PROTOCOL command.