This characteristic attribute indicates the first time at which the DSA is to write its database to disk and open a new update log file. Syntax: SET DSA DIT CHECK START TIME "<time>" SHOW DSA DIT CHECK START TIME where <time> is the required time specified in binary absolute time. For example, if you want the DSA to write the database for the first time at midday, enter the following: > SET DSA DIT CHECK START TIME "12:00" The DSA then writes the database to disk at regular intervals after the specified start time. The intervals are defined by the DIT Check Interval attribute.