set [node node-id] mop circuit circuit-name ...
Modifies the attributes for a mop circuit entity, which is
a data link circuit on which MOP services are available. The
modifiable attributes and their data types [in brackets] are:
known clients only [boolean]
link name [data-link-entity-name]
retransmit timer [seconds]
Refer to attributes for specific command examples.
1 – known_clients_only
Default: False Value: True or false
Specifies whether MOP attempts to service load requests from
remote systems which do not have a corresponding client entity.
Some network servers are designed to request specific software
by name, and in such a case there is no need for a client entity
to exist. By default, MOP tries to process requests for named
software from unknown clients. Set this attribute to true if you
wish MOP to ignore such requests.
set [node node-id] mop circuit circuit-name -
known clients only boolean
Example:
set mop circuit fddi-1 known clients only true
2 – link_name
Default: No name Value: Data link entity name
Name of a station entity in the Data Link layer module indicated
by the type characteristic. This name is passed to the Data Link
layer module when MOP opens a portal for the circuit.
set [node node-id] mop circuit circuit-name -
link name data-link-entity-name
3 – retransmit_timer
Default: 4 Value: 1-30
Time, in seconds, to wait for a response before retransmitting a
MOP protocol message.
set [node node-id] mop circuit circuit-name -
retransmit timer integer
Example:
set mop circuit fddi-1 retransmit timer 4