/sys$common/syshlp/MSA_UTIL_HELP.HLB  —  SmartArray  Restriction
         - The MSA_UTIL command "SHOW CONNECTIONS" is not
           applicable or is not supported on the HP StorageWorks Smart
           Array Controller.

         - Extend, Migrate and Expand commands on Smart Arrays will
           fail if the controller cache is bad or the cache battery is
           less than 75%. These commands will work on controllers that
           are designed to support volume expansion by using disk drives
           for backing up expand data stripe. This is in the absence of
           battery backed memory on the controller.

         - RAID units that have spare disks (RAID 1, RAID 5 and so on)
           cannot be migrated to RAID 0 or JBOD units.

         - Multiple capacity disks can be used by specifying the "/SIZE"
           qualifier. The maximum value of size specified with the "/SIZE"
           qualifier should be the size available on the disk with the
           lowest capacity.
Close Help