Library /sys$common/syshlp/MSA_UTIL_HELP.HLB  —  SHOW  CONTROLLER
                 SHOW CONTROLLER displays the specified controller's
                 information if the controller name is provided. If
                 the controller name is not provided, then information
                 of all the connected controllers is displayed.

                 The SHOW CONTROLLER command is synonymous to the
                 SHOW ADAPTER command.

                 Note: If the context is set to a specific controller
                       and the controller name is not provided, then
                       SHOW CONTROLLER displays information pertaining
                       only to the controller to which the context is
                       set.

                 Format:
                         SHOW CONTROLLER (Controller_name:) / <qualifiers>

1  –  Parameters

                 Controller_name:

2  –  Qualifiers

2.1    /BUS

                 Displays the Bus number of the controller.

2.2    /BRIEF

                 Displays limited information of the controller.

2.3    /DEFAULT

                 Displays information of the default controller.

2.4    /NODEFAULT

                 Displays information of all the controllers.

2.5    /FULL

                 Displays extensive information of the controller.

2.6    /REVISION

                 Displays the firmware version of the controller along
                 with the default information for the controller.

2.7    /SUBSYSTEM

                 Displays the Subsystem ID of the controller.

2.8    /VERBOSE

                 Provides logging that can be interpreted by engineering.

3  –  Examples

                 MSA> SHOW CONTROLLER

                 A default controller is not set.  All matching controllers
                 displayed

                 Controller: _$1$GGA201:
                 MSA1000     (c) COMPAQ      P56350B9IN2021 Software 4.42
                 Controller Identifer: 201
                 NODE_ID = 500805f3-0001b660
                 SCSI_VERSION = SCSI-3
                 Supported Redundancy Mode: Active/Standby
                 Current Redundancy mode: Active/Standby
                 Current Role: Standby
                 Device Port SCSI address 6
                 Host Port_1:
                      REPORTED PORT_ID = 500805f3-0001b669
                      PORT_1_TOPOLOGY = Not available to this program
                 Cache:
                     102 megabyte read cache   154 megabyte write cache
                     Cache is GOOD, and Cache is enabled.
                     No unflushed data in cache.
                 Battery:
                     Battery is fully charged.

                 Controller: _$1$GGA300:
                 MSA CONTROLLER   (c) HP      P56350GX3QN152 Software 6.72
                 Controller Identifier: 300
                 NODE_ID = 500508b3-00905ed0
                 SCSI_VERSION = SCSI-3
                 Supported Redundancy Mode: Asym Active/Active  Active/Standby
                     Current Redundancy mode: Asymmetrical Active/Active
                     Current Role: Active
                     Device Port SCSI address 7
                 Host Port_1:
                     REPORTED PORT_ID = 500508b3-00905ed1
                     PORT_1_TOPOLOGY = Not available to this program
                 Cache:
                     128 megabyte read cache   128 megabyte write cache
                     Cache is GOOD, and Cache is enabled.
                     No unflushed data in cache.
                 Battery:
                     Battery is fully charged.

                 Controller: _$1$GGA301:
                 MSA CONTROLLER   (c) HP      P56350GX3QN0FS Software 6.72
                 Controller Identifier: 301
                 NODE_ID = 500508b3-00905ed0
                 SCSI_VERSION = SCSI-3
                 Supported Redundancy Mode: Asym Active/Active  Active/Standby
                    Current Redundancy mode: Asymmetrical Active/Active
                    Current Role: Active
                    Device Port SCSI address 6
                 Host Port_1:
                    REPORTED PORT_ID = 500508b3-00905ed9
                    PORT_1_TOPOLOGY = Not available to this program
                 Cache:
                    128 megabyte read cache   128 megabyte write cache
                    Cache is GOOD, and Cache is enabled.
                    No unflushed data in cache.
                 Battery:
                    Battery is fully charged.

                 Controller: _$1$GGA1002:
                 MSA1000    (c) COMPAQ       P56350A9IMN06M Software 4.42
                 Controller Identifier: 1002
                 NODE_ID = 500805f3-0001b660
                 SCSI_VERSION = SCSI-3
                 Supported Redundancy Mode: Active/Standby
                    Current Redundancy mode: Active/Standby
                    Current Role: Active
                    Device Port SCSI address 7
                 Host Port_1:
                    REPORTED PORT_ID = 500805f3-0001b661
                    PORT_1_TOPOLOGY = Not available to this program
                 Cache:
                    102 megabyte read cache   154 megabyte write cache
                    Cache is GOOD, and Cache is enabled.
                    No unflushed data in cache.
                 Battery:
                    Battery is fully charged.

                 Adapter: _PKD0:
                 SA6400      (c) HP       P57820FDAPHJE7 Software 1.92
                 SCSI_VERSION = X3.131:1994 (SCSI-2)
                 Not currently Redundant
                 Current Role: Active
                 (No redundant controller installed)
                 Cache:
                    128 megabyte read/write cache
                    Cache is not configured, and Cache is disabled.
                    No unflushed data in cache.
                 Battery:
                     Battery is not fully charged.

                 Adapter: _PKE0:
                 SA6400 EM     (c) HP      P577C0EDAPH3JK Software 1.92
                 SCSI_VERSION = X3.131:1994 (SCSI-2)
                 Not currently Redundant
                 Current Role: Active
                 (No redundant controller installed)
                 Cache:
                     128 megabyte read/write cache
                     Cache is not configured, and Cache is disabled.
                     No unflushed data in cache.
                 Battery:
                     Battery is not fully charged.
Close Help