Validates all parameter values to ensure that they fall within the defined minimum and maximum values. Because range checks are enabled by default, use PARAMETERS ENABLE CHECKS after entering a PARAMETERS DISABLE CHECKS command. Format PARAMETERS ENABLE CHECKS
1 – Example
SYSMAN> PARAMETERS DISABLE CHECKS SYSMAN> PARAMETERS SET WSMAX 20 SYSMAN> PARAMETERS ENABLE CHECKS SYSMAN> PARAMETERS SET WSMAX 30 %SMI-E-OUTRANGE, parameter is out of range SYSMAN> PARAMETERS SHOW WSMAX Parameter Name Current Default Minimum Maximum Unit Dynamic WSMAX 2000 1024 60 6400 pages The PARAMETERS ENABLE CHECKS command in this example shows that when range checking is disabled, the system accepts a working set value (WSMAX) of 20. However, once range checking is enabled with the PARAMETERS ENABLE CHECKS command, the system does not accept a WSMAX below the minimum, which is 60.