Differentiates between the active, inactive and dying DDCMP timer parameters
1 – BASE
Applies to DDCMP CONTROL circuits. This value sets the base priority of an Dying tributary after the tributary has been polled. You can set a separate base for each of the indicated polling states. Base must be a decimal integer from 0 to 255. If not specifically set, the DYING BASE default is 0.
2 – INCREMENT
Applies to DDCMP CONTROL circuits. This parameter sets the increment value added to the DYING tributary priority each time the scheduling timer expires. Increment must be a decimal integer from 0 to 255. If not specifically set, the DYING INCREMENT default is 16.
3 – THRESHOLD
Applies to DDCMP CONTROL circuits. It specifies the number of times to poll the active or inactive tributary before changing that tributary's polling state to dying because of receive timeouts. Count must be a decimal integer in the range 0 to 255. The default count is 2.