set [node node-id] modem connect line line-name ...
Modifies the attributes for an modem connect line entity, which is
associated with a physical circuit on the node. The modifiable
attributes and their data types [in brackets] are:
alternate speed [bits-per-second]
call accept timer [milliseconds]
carrier loss timer [milliseconds]
clock [external, internal, or reflected]
encoding [normal or nrzi]
initial hold timer [seconds] (Tru64 UNIX)
maximum call setup timer [seconds]
maximum disable transmit timer [milliseconds]
maximum dsr deassertion timer [milliseconds]
maximum enable transmit timer [milliseconds]
minimum dtr deassertion timer [milliseconds]
modem control [full or none]
modem options [dialout, direct or rate select]
modem protocol format [type] (Tru64 UNIX)
modem protocol type [prot-type] (Tru64 UNIX)
rate select [high or low]
speed [bits-per-second]
successful call indication timer [seconds]
suppress test indicator [boolean]
transmit holdoff timer [milliseconds]
Additional Information:
explode
extract