I64 systems only. Determines the program's initial floating point mode when one is not provided by the module that provides the main transfer address. Format /FP_MODE=keyword /NOFP_MODE (default)
1 – Qualifier Values
keyword The OpenVMS I64 Linker accepts the following keywords to set the floating point mode: Keyword Description D_FLOAT, G_FLOAT Sets VAX floating point modes. IEEE_FLOAT[=ieee_ Sets the IEEE floating point mode to behavior] the default or a specific behavior. The OpenVMS I64 Linker accepts the following IEEE behavior keywords: FAST UNDERFLOW_TO_ZERO DENORM_RESULTS (default) INEXACT LITERAL=fp_ctrl_mask Sets the floating point mode to a literal control mask. You can express this mask as a decimal (%D), octal (%O), or hexadecimal (%X) value (for example %X09800000, which is equivalent to the default, IEEE_ FLOAT=DENORM_RESULTS).